United Kingdom

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

Are you an Electrician?
Schneider Eletric XY2SB71 Picture

View all Preventa XY2 SB

Preventa XY2 SB - XY2SB71

Products

Schneider Eletric XY2SB71 Picture
View all Preventa XY2 SB
Preventa XY2 SB - XY2SB71
Products

2-hand control station - 2 pushbuttons + 1 Emergency Stop mushroom head

Show more characteristics >
  • RRP
    396.33 GBP
Add to My Products Add to My Products

  • Main
    range of product
    Preventa XY2
    product or component type
    Two-hand control station
    component name
    XY2S
    control station composition
    2 push-buttons + 1 emergency stop push-button
    control button type
    1 push-button, mushroom, red, 1 NC + 1 NC simultaneous
    2 push-buttons, 1 NC + 1 NO break before make
    Complementary
    housing colour
    Orange RAL 2008
    surface finish
    Painted
    cable entry
    1 plain hole for M25
    2 plain holes for M20
    mechanical durability
    1000000 cycles
    contact code designation
    AC-15, A600 or 240 V, 3 A
    DC-13, Q600 or 250 V, 0.27 A conforming to EN/IEC 60947-5-1 appendix A
    [Ui] rated insulation voltage
    600 V conforming to CSA C22.2 No 14
    600 V conforming to UL 508
    600 V, degree of pollution: 3 conforming to EN/IEC 60947-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to EN/IEC 60947-1
    positive opening
    With conforming to EN/IEC 60947-5-1 appendix K
    short-circuit protection
    10 A fuse protection by cartridge fuse type gG conforming to EN/IEC 60269
    electrical durability
    1000000 cycles utilisation category AC-15, operating rate: 60 cyc/mn at 120 V, 3 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category AC-15, operating rate: 60 cyc/mn at 230 V, 2 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category AC-15, operating rate: 60 cyc/mn at 24 V, 4 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category DC-13, operating rate: 60 cyc/mn at 110 V, 0.2 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    1000000 cycles utilisation category DC-13, operating rate: 60 cyc/mn at 24 V, 0.5 A, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
    electrical reliability
    Failure rate < 0.00000001 at 17 V, 0.005 A conforming to EN/IEC 60947-5-4
    Failure rate < 0.000001 at 5 V, 0.001 A conforming to EN/IEC 60947-5-4
    product weight
    4 kg
    Environment
    standards
    EN 574
    EN/IEC 60947-5-1
    ISO 13851
    protective treatment
    TC
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    5 gn (f = 2...500 Hz) conforming to EN/IEC 60068-2-6
    shock resistance
    10 gn for 11 ms conforming to EN/IEC 60068-2-27
    electrical shock protection class
    Class I conforming to EN/IEC 61140
    IP degree of protection
    IP65 conforming to EN/IEC 60529
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product end of life instructions
    Need no specific recycling operations
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Enabling movement -Two-hand ergonomic control stations XY2SB (Version 1.0)
    CAD
    Date
    Size
    Add to My Documents
    Declaration of conformity
    Date
    Size
    Add to My Documents
    XY2SB Two-hand control unit (Version 1.0)
    Date 14/11/18
    Size 354.9 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XY2SB Ergonomic 2 hands control stations range, Product Environmental Profile (Version 1.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Control Station
    Dimensions


    (1)
    2 plain holes for n° 13 (PG13.5) or ISO M20 cable gland.
    (2)
    Ø 56 mm/Ø 2.20 in. knock-out specifically for mounting on pedestal.
    (3)
    1 plain hole for n° 21 (PG21) cable gland. For ISO M25, use adaptor DE9RA2125 and fixing nut DE9EC21.