multifunction control relay RM17-TA - range 183..528 V AC

Show more characteristics >
  • RRP
    112.18 GBP
Add to My Products Add to My Products

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Multifunction control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TA
    relay monitored parameters
    Asymmetry
    Phase failure detection
    Phase sequence
    time delay
    Adjustable 0.1...10 s, +/- 10 % of the full scale value
    switching capacity in VA
    1250 VA
    measurement range
    208...480 V voltage AC
    Complementary
    reset time
    1500 ms for time delay
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    5 A DC
    supply voltage limits
    183...528 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0...22 VA at 400 V AC 50 Hz
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    1 C/O
    nominal output current
    5 A
    measurement voltage limits
    183...528 V AC
    hysteresis
    2 %
    delay at power up
    <= 650 ms
    measuring cycle
    <= 150 ms measurement cycle as true rms value
    threshold adjustment voltage
    +2...+17 % in the range 480 V AC
    -2...-12 % in the range 208 V AC
    -2...-17 % in the range 220 V AC
    2...20 % of Un selected
    voltage range
    208...480 V phase to phase
    adjustment of asymmetry threshold
    5...15 % of Un selected
    repeat accuracy
    0.5 % for input and measurement circuit
    3 % for time delay
    measurement error
    < 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    phase failure sensitivity
    0.7 Un
    response time
    < 200 ms in the event of a fault
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without
    connections - terminals
    Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED green for power ON
    LED yellow for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    <= 30000000 cycles
    operating rate
    <= 360 operations/hour under full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 502.2 years
    B10d = 470000
    width
    17.5 mm
    product weight
    0.13 kg
    Environment
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    CSA
    C-Tick
    GL
    GOST
    UL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV 1 min AC 50 Hz conforming to IEC 60255-5
    2 kV 1 min AC 50 Hz conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • German
    Software - Released
    Date
    Size
    Add to My Documents
    ZelioControl Soft (Version 1.6)
    Date 14/01/19
    Size 3.1 MB
    Catalogue
    Date
    Size
    Add to My Documents
    Zelio Control - Monitoring & Control Relays catalog (Version 2.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    RM17 T.00 Multifunction 3-phase supply control, Instruction Sheet (Version 04)
    CAD
    Date
    Size
    Add to My Documents
    CAD files for RM17TA00: Zelio Control (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)
    Zelio Control RM10 RM17 CCC Certificate (Version 1.0)
    CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    RM17... Measurement relays, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Multifunction 3-Phase Supply Control Relays
    Dimensions and Mounting



  • Connections and Schema

    Multifunction 3-Phase Supply Control Relays
    Wiring Diagram



  • Technical Description

    Function Diagram
    Phase Sequence Control, Phase Failure Detection (U measured < 0.7 x nominal supply voltage), and Asymmetry Detection


    Legend

    Tt Time delay after crossing of threshold

    L1, L2, L3 Phases of the supply voltage monitored

    A Asymmetry threshold

    H Hysteresis

    11-12, 11-14 Output relay connections

    Relay status: black color = energized.