United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region
Are you an Electrician?

Multifunction Timer Relay - 12V AC/DC - 2 C/O

Show more characteristics >
  • RRP
    52.57 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    device short name
    RE22
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O timed contact
    1 C/O timed or instantaneous contact
    time delay type
    B
    C
    Di
    Ht
    Bw
    Ac
    H
    At
    A
    D
    time delay range
    1...10 min
    6...60 min
    0.1...1 s
    6...60 s
    1...10 s
    1...10 h
    10...100 h
    control type
    Rotary knob front panel
    [Us] rated supply voltage
    12 V AC/DC
    voltage range
    0.9...1.2 Us
    supply frequency
    50...60 Hz +/- 5 %
    connections - terminals
    Screw terminals, 2 x 1.5 mm² with cable end
    Screw terminals, 2 x 2.5 mm² without cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % conforming to IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
    Control signal pulse width
    30 ms
    100 ms under load
    insulation resistance
    100 MOhm at 500 V DC conforming to IEC 60664-1
    Recovery time
    120 ms on de-energisation
    immunity to microbreaks
    10 ms
    power consumption in VA
    1.2 VA at 12 V AC
    power consumption in W
    0.5 W at 12 V DC
    breaking capacity
    2000 VA
    minimum switching current
    10 mA at 5 V
    maximum switching current
    8 mA
    maximum switching voltage
    250 V
    electrical durability
    100000 cycles for resistive load, 8 A at 250 V, AC
    mechanical durability
    10000000 cycles
    Rated impulse withstand voltage
    5 kV for 1.2…50 µs conforming to IEC 60664-1
    5 kV conforming to IEC 61812-1
    Power on delay
    100 ms
    safety reliability data
    B10d = 190000
    MTTFd = 205.4 years
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    status LED
    Green LED (flashing) for timing in progress
    Green LED (steady) for power ON
    Yellow LED for relay energised
    width
    22.5 mm
    net weight
    0.09 kg
    Environment
    dielectric strength
    2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1
    standards
    EN 61000-6-1
    IEC 61812-1
    EN 61000-6-4
    EN 61000-6-3
    EN 61000-6-2
    directives
    2006/95/EC - low voltage directive
    2004/108/EC - electromagnetic compatibility
    product certifications
    CSA
    CULus
    China RoHS
    CE
    EAC
    GL
    CCC
    RCM
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -30…60 °C
    IP degree of protection
    Housing: IP40 conforming to IEC 60529
    Terminal block: IP20 conforming to IEC 60529
    Front face: IP40 conforming to IEC 60529
    vibration resistance
    20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity
    93 %, without condensation conforming to IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test - test level: 6 kV (contact discharge)level 3 conforming to EN/IEC 61000-4-2
    Electrostatic discharge immunity test - test level: 8 kV (air discharge)level 3 conforming to EN/IEC 61000-4-2
    Fast transients immunity test - test level: 1 kV (capacitive connecting clip)level 3 conforming to IEC 61000-4-4
    Fast transients immunity test - test level: 2 kV (direct contact)level 3 conforming to IEC 61000-4-4
    Surge immunity test - test level: 1 kV (differential mode)level 3 conforming to IEC 61000-4-5
    Surge immunity test - test level: 2 kV (common mode)level 3 conforming to IEC 61000-4-5
    Radiated radio-frequency electromagnetic field immunity test - test level: 10 V (0.15...80 MHz)level 3 conforming to IEC 61000-4-6
    Electromagnetic field immunity test - test level: 10 V/m (80 MHz...1 GHz)level 3 conforming to IEC 61000-4-3
    Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
    Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
    Conducted and radiated emissionsclass B conforming to EN 55022
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Not applicable, out of EU RoHS legal scope
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • Documents and Downloads

    Language
    • English
    • Slovak
    • Spanish
    • Slovenian
    • French
    • Serbian
    • Finnish
    • Chinese
    • Hungarian
    • Norwegian
    • Dutch
    • Turkish
    • Russian
    • Lithuanian
    • Greek
    • Czech
    • Croatian
    • Polish
    • Italian
    • Romanian
    • German
    • Swedish
    Catalogue
    Date
    Size
    Add to My Documents
    Zelio Time Timing Relays catalog (Version 8.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    RE22... Timing relays (Industrial single, dual or multifunction relays), Instruction Sheet (Version 00)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for RE22R2MJU: Multifunction Timer Relay - 12V AC/DC - 2 C/O (Version 2.0)
    Industrial timing relay multifunction (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)
    Zelio Timer RE22 and RENF22R2MMW (Version 1.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    EU DOC - Zelio Timer RE22 (Version 1.0)
    Date 20/04/16
    Size 243.3 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    RE22... Timer Relay - Zelio Time, Product End-of-Life Instructions (Version 2.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 23/08/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    RE22... Timing Relay - Zelio Time, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 23/08/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 23/08/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram



  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energization. After timing, the output(s) relay close(s).


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Ac : On- and Off-Delay Relay with Control Signal
    Description

    After power-up, closing of the control contact Y1 causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes.

    When control contact Y1 re-opens, the timing T starts.At the end of this timing period T

    At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function At : Power on Delay Relay (Summation) with Control Signal
    Description

    After power-up, the first opening of control contact Y1 starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.


    T = t1+t2+t3


    Function B : Interval Relay with Control Signal
    Description

    After power-up, pulsing or maintaining control contact Y1 starts the timing T. The output relay closes for the duration of the timing period T then reverts to its initial state.



    Function Bw : Double Interval Relay with Control Signal
    Description

    On closing and opening of control contact Y1, the output relay closes for the duration of the timing period T.



    Function C : Off-Delay Relay with Control Signal
    Description

    After power-up and closing of the control contact Y1, the output relay closes. When control contact Y1 re-opens, timing T starts. At the end of the timing period, the output(s) relay revert(s) to its/their initial state.


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D : Symmetrical Flasher Relay (Starting Pulse Off)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.


    Before power-up Y1 should be permanently connected to A1.

    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D : Symmetrical Flasher Relay (Starting Pulse On)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function H : Interval Relay
    Description

    On energization of the relay, timing period T starts and the output(s) relay close(s). At the end of the timing period T, the output(s) relay revert(s) to its/their initial state


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    Y1 :

    Control contact

    R1/R2 :

    2 timed outputs

    R2 inst. :

    The second output is instantaneous if the right position is selected

    T :

    Timing period

    U :

    Supply


    Function Ht : Interval Relay (Summation) with Control Signal
    Description

    On energization, the output relay closes for the duration of a timing period T then reverts to its initial state.

    Pulsing or maintaining control contact Y1 will again close the output relay.

    Timing T is only active when control contact Y1 is released and so the output relay will not revert to its initial state until after a time t1 + t2 + t3

    The relay memories the total, cumulative opening time of control contact Y1 and, once the set time T is reached, the output relay reverts to its initial state.


    T = t1+t2+t3

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    Y1 :

    Control contact

    R1/R2 :

    2 timed outputs

    R2 inst. :

    The second output is instantaneous if the right position is selected

    T :

    Timing period

    U :

    Supply


Compare products: /