Range: TeSys U

Power base

LUB32TQ

Schneider Eletric LUB32TQ Picture
Range: TeSys U

Power base

LUB32TQ

power base - TeSys U - 32 A - screw clamps control - set of 10

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys U
    device short name
    LUB
    product or component type
    Non reversing power base
    device application
    Motor
    poles description
    3P
    suitability for isolation
    Yes
    [Ith] conventional free air thermal current
    32 A
    utilisation category
    AC-41
    AC-43
    AC-44
    quantity per set
    Set of 10
    Complementary
    auxiliary contact composition
    1 NO + 1 NC
    auxiliary contacts type
    Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
    Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
    [Ue] rated operational voltage
    230 V
    440 V
    500 V
    690 V
    network frequency
    40...60 Hz
    [Ie] rated operational current
    21 A at 690 V
    23 A at 500 V
    32 A at <= 440 V
    [Ics] rated service breaking capacity
    10 kA 500 V
    4 kA 690 V
    50 kA 230 V
    50 kA 440 V
    typical current consumption
    200 mA at 24 V DC I maximum while closing with LUCM
    220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    75 mA at 24 V DC I rms sealed with LUCM
    80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    safety reliability level
    B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    operating time
    35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
    50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
    60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
    65 ms closing with LUCM for control circuit
    70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
    mechanical durability
    15000000 cycles
    operating rate
    60 cyc/mn
    [Ui] rated insulation voltage
    600 V conforming to CSA C22.2 No 14
    600 V conforming to UL 508
    690 V conforming to IEC 60947-1 3
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-6-2
    safe separation of circuit
    400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
    400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
    connections - terminals
    Power circuit : screw clamp terminals 2 cable 1.5...6 mm² - cable stiffness: flexible - without cable end
    Control circuit : screw clamp terminals 1 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end
    Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end
    Control circuit : screw clamp terminals 1 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end
    Control circuit : screw clamp terminals 2 cable 0.34...1.5 mm² - cable stiffness: flexible - with cable end
    Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: flexible - without cable end
    Control circuit : screw clamp terminals 2 cable 0.75...1.5 mm² - cable stiffness: rigid - without cable end
    Power circuit : screw clamp terminals 1 cable 1...10 mm² - cable stiffness: rigid - without cable end
    Power circuit : screw clamp terminals 1 cable 1...6 mm² - cable stiffness: flexible - with cable end
    Power circuit : screw clamp terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end
    Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: flexible - with cable end
    Power circuit : screw clamp terminals 2 cable 1...6 mm² - cable stiffness: rigid - without cable end
    tightening torque
    Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm flat
    Control circuit : 0.8...1.2 N.m - with screwdriver 5 mm Philips no 1
    Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm flat
    Power circuit : 1.9...2.5 N.m - with screwdriver 6 mm Philips No 2
    width
    45 mm
    height
    145 mm
    depth
    126 mm
    product weight
    0.9 kg
    Environment
    heat dissipation
    3 W for control circuit with LUCA, LUCB, LUCC, LUCD
    1.8 W for control circuit with LUCM
    immunity to microbreaks
    3 ms
    immunity to voltage dips
    70 % 500 ms conforming to IEC 61000-4-11
    product certifications
    ABS
    ASEFA
    ATEX
    BV
    CCC
    CSA
    DNV
    GL
    GOST
    LROS (Lloyds register of shipping)
    UL
    standards
    CSA C22.2 No 14 type E
    EN 60947-6-2
    IEC 60947-6-2
    UL 508 type E with phase barrier
    IP degree of protection
    IP20 front panel and wired terminals conforming to IEC 60947-1
    IP20 other faces conforming to IEC 60947-1
    IP40 front panel outside connection zone conforming to IEC 60947-1
    protective treatment
    TH conforming to IEC 60068
    ambient air temperature for operation
    -25...60 °C with LUCM
    -25...70 °C with LUCA, LUCB, LUCC, LUCD
    ambient air temperature for storage
    -40...85 °C
    fire resistance
    650 °C conforming to IEC 60695-2-12
    960 °C parts supporting live components conforming to IEC 60695-2-12
    operating altitude
    2000 m
    shock resistance
    10 gn power poles open conforming to IEC 60068-2-27
    15 gn power poles closed conforming to IEC 60068-2-27
    vibration resistance
    2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27
    4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
    resistance to electrostatic discharge
    8 kV level 3 in open air conforming to IEC 61000-4-2
    8 kV level 4 on contact conforming to IEC 61000-4-2
    resistance to radiated fields
    10 V/m 3 conforming to IEC 61000-4-3
    resistance to fast transients
    2 kV class 3 serial link conforming to IEC 61000-4-4
    4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
    non-dissipating shock wave
    1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2
    1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
    2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
    2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
    immunity to radioelectric fields
    10 V conforming to IEC 61000-4-6
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    Date 22/12/17
    Size 1.5 MB
    Date 22/12/17
    Size 868 KB
    Date 08/01/18
    Size 3.5 MB
    Date 06/09/18
    Size 503.7 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 14/07/18
    Size 7.8 MB
    CAD
    Date
    Size
    Add to My Documents
    SCREW CLAMP BASE
    Date 21/02/18
    Size 489.6 KB
    Date 21/02/18
    Size 692 KB
    Certificate
    Date
    Size
    Add to My Documents
    Date 14/07/18
    Size 1.9 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 10/11/17
    Size 76.8 KB
    Date 10/11/17
    Size 76.7 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Date 03/03/16
    Size 271.4 KB
    Date 18/09/17
    Size 179 KB
    Date 15/11/16
    Size 169.2 KB
    Product environmental
    Date
    Size
    Add to My Documents
    Date 03/03/16
    Size 399.8 KB
    Date 30/11/17
    Size 189.4 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.