United Kingdom

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

Are you an Electrician?

TeSys LRD thermal overload relays - 0.16...0.25 A - class 10A

Show more characteristics >
  • RRP
    55.05 GBP
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys LRD
    product or component type
    Non differential thermal overload relay
    device short name
    LR3D
    relay application
    Motor protection
    product compatibility
    LC1D25
    LC1D12
    LC1D38
    LC1D18
    LC1D09
    LC1D32
    network type
    DC
    AC
    thermal protection adjustment range
    0.16...0.25 A
    [Ui] rated insulation voltage
    600 V power circuit conforming to CSA
    600 V power circuit conforming to UL
    690 V power circuit conforming to IEC 60947-4-1
    Complementary
    network frequency
    0...400 Hz
    mounting support
    Plate with specific accessories
    Rail with specific accessories
    Under contactor
    tripping threshold
    1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
    [Ith] conventional free air thermal current
    5 A for signalling circuit
    permissible current
    3 A at 120 V AC-15 for signalling circuit
    0.22 A at 125 V DC-13 for signalling circuit
    [Ue] rated operational voltage
    690 V AC 0...400 Hz
    [Uimp] rated impulse withstand voltage
    6 kV
    phase failure sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0
    control type
    Red push-button stop
    Blue push-button for reset mode
    temperature compensation
    -20...60 °C
    connections - terminals
    Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² flexible without cable end
    Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² flexible with cable end
    Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² solid without cable end
    Power circuit : screw clamp terminals 1 cable(s) 1.5...10 mm² flexible without cable end
    Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² flexible with cable end
    Power circuit : screw clamp terminals 1 cable(s) 1...6 mm² solid without cable end
    tightening torque
    Control circuit : 1.7 N.m on screw clamp terminals
    Power circuit : 1.7 N.m on screw clamp terminals
    width
    45 mm
    depth
    70 mm
    product weight
    0.124 kg
    Environment
    protective treatment
    TH conforming to IEC 60068
    IP degree of protection
    IP20 conforming to IEC 60529
    ambient air temperature for operation
    -20...60 °C without derating conforming to IEC 60947-4-1
    ambient air temperature for storage
    -60...70 °C
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations 6 Gn IEC 60068-2-6
    Shocks 15 Gn for 11 ms IEC 60068-2-7
    dielectric strength
    6 kV at 50 Hz conforming to IEC 60255-5
    standards
    EN 60947-5-1
    IEC 60947-4-1
    ATEX D 94/9/CE
    EN 60947-4-1
    CSA C22.2 No 14
    IEC 60947-5-1
    UL 508
    product certifications
    ATEX INERIS
    RINA
    GL
    UL
    CSA
    BV
    DNV
    LROS (Lloyds register of shipping)
    CCC
    GOST
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    • German
    • Chinese
    User guide
    Date
    Size
    Add to My Documents
    TeSys D/LRD Thermal Overload Relays up to 15 kW - Use in explosive atmospheres (Version 05)
    Instruction sheet
    Date
    Size
    Add to My Documents
    LRD, LR3D, LR7D - Thermal overload relay up to 15 kW (Version 08)
    LRD, LR3D - Thermal overload relay up to 15 kW (instruction sheet printed on the box) (Version 07)
    CAD
    Date
    Size
    Add to My Documents
    Differential thermal overload relays Class 10 A & 20 A for connection by screw clamp terminals or connectors (Version 1.0)
    CAD for LR3D02: TeSys LRD thermal overload relays - 0.16...0.25 A - class 10A (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate TeSys LR.D - LRD01-35 Cl10 Thailand (Version 1.0)
    CB Certificate TeSys LR.D - LRD01-35 Cl10 France (Version 1.0)
    ATEX TeSys LRD - LRD01-35_LRD04L-32L (Version 1.0)
    CCC Certificate TeSys LRD - LRD01-35, Thailand (Version 1.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    EU Declaration TeSys LRD - LRD01-35_LRD04L-32L (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 25/05/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP - TeSys D LC1D01 to D38 contactors (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 25/05/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.