
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 95 A - 230 V AC coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Resistive loadMotor controlutilisation category AC-3AC-1device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 300 V DC for power circuit<= 1000 V AC 25...400 Hz for power circuit[Ie] rated operational current 125 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit95 A (<= 60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 25 kW at 220...230 V AC 50/60 Hz45 kW at 1000 V AC 50/60 Hz45 kW at 380...400 V AC 50/60 Hz45 kW at 660...690 V AC 50/60 Hz55 kW at 500 V AC 50/60 Hz45 kW at 415...440 V AC 50/60 Hzmotor power HP (UL / CSA) 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors7.5 hp at 115 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors25 hp at 230/240 V AC 50/60 Hz for 3 phases motors60 hp at 460/480 V AC 50/60 Hz for 3 phases motors60 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 230 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 125 A at <= 60 °C for power circuit10 A at <= 60 °C for signalling circuitIrms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 1100 A <= 40 °C 1 s power circuit135 A <= 40 °C 10 min power circuit400 A <= 40 °C 1 min power circuit800 A <= 40 °C 10 s power circuit100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuitassociated fuse rating 160 A gG at <= 690 V coordination type 2 for power circuit200 A gG at <= 690 V coordination type 1 for power circuit10 A gG for signalling circuit conforming to IEC 60947-5-1average impedance At 50 Hz - Ith 125 A for power circuit[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 1.2 Mcycles 95 A AC-3 at Ue <= 440 V1.3 Mcycles 125 A AC-1 at Ue <= 440 Vpower dissipation per pole 7.2 W AC-312.5 W AC-1safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications BVGLCCCRINADNVGOSTLROS (Lloyds register of shipping)connections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endPower circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - without cable endPower circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: flexible - without cable endPower circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - with cable endPower circuit : connector 2 cable(s) 4...16 mm² - cable stiffness: flexible - with cable endPower circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: solid - without cable endPower circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: solid - without cable endtightening torque Power circuit : 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mmPower circuit : 9 N.m - on connector hexagonal 4 mmControl circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2operating time 20...35 ms closing6...20 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 4 Mcyclesoperating rate 3600 cyc/h at <= 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits 0.85...1.1 Uc operational at 55 °C, AC 60 Hz0.3...0.6 Uc drop-out at 55 °C, AC 50/60 Hz0.8...1.1 Uc operational at 55 °C, AC 50 Hzinrush power in VA 245 VA at 20 °C (cos ϕ 0.75) 60 Hz245 VA at 20 °C (cos ϕ 0.75) 50 Hzhold-in power consumption in VA 26 VA at 20 °C (cos ϕ 0.3) 60 Hz26 VA at 20 °C (cos ϕ 0.3) 50 Hzheat dissipation 6...10 W at 50/60 Hzauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V Signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzShocks contactor open 8 Gn for 11 msVibrations contactor closed 3 Gn, 5...300 HzShocks contactor closed 10 Gn for 11 msheight 127 mmwidth 182 mmdepth 158 mmproduct weight 3.2 kgOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Need no specific recycling operationsContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
CADSizeAdd to My DocumentsREVERSING CONTACTOR (Version 1.0)CertificateSizeAdd to My DocumentsCCC TeSys D - LC.D80-95, Czech Republic (Version 1.0)Declaration of conformitySizeAdd to My DocumentsEU Declaration TeSys D - LC.D80-95 (Version 1.0)Product Environmental ProfileSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
DimensionsLC2 or 2 x LC1
a
b
c
e1
e2
G
G1
D80 and D95 (AC)
182
127
158
13
–
57
96
c, e1 and e2: including cabling.
-
Connections and Schema
Wiring