United Kingdom

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

Schneider Eletric LC2D65G5 Picture

View all Schneider Legacy Products

Schneider Legacy Products - LC2D65G5

Industry

Schneider Eletric LC2D65G5 Picture
View all Schneider Legacy Products
Schneider Legacy Products - LC2D65G5
Industry

reversing contactor TeSys LC2-D - 3 poles - AC-3 440V 65 A - coil 120 V AC

Show more characteristics >
  • RRP
    585.59 GBP
Add to My Products Remove from My Products

  • Main
    range of product
    TeSys D
    product or component type
    Reversing contactor
    device short name
    LC2D
    contactor application
    Motor control
    utilisation category
    AC-2
    AC-3
    AC-4
    control circuit type
    AC
    coil type
    Standard
    poles description
    3P
    pole contact composition
    3 NO
    [Ie] rated operational current
    65 A (<= 60 °C) AC network AC-3 for power circuit
    motor power kW
    30 kW at 380...400 V AC 50/60 Hz
    37 kW at 415 V AC 50/60 Hz
    37 kW at 440 V AC 50/60 Hz
    37 kW at 500 V AC 50/60 Hz
    37 kW at 660...690 V AC 50/60 Hz
    18.5 kW at 220...240 V AC 50/60 Hz
    [Uc] control circuit voltage
    120 V AC 50 Hz
    connections - terminals
    Control circuit : screwclamp terminal 1 cable 1...4 mm² - cable stiffness: flexible - with cable end
    Control circuit : screwclamp terminal 1 cable 1...4 mm² - cable stiffness: flexible - without cable end
    Control circuit : screwclamp terminal 1 cable 1...4 mm² - cable stiffness: solid - without cable end
    Control circuit : screwclamp terminal 2 cable 1...2.5 mm² - cable stiffness: flexible - with cable end
    Control circuit : screwclamp terminal 2 cable 1...4 mm² - cable stiffness: flexible - without cable end
    Control circuit : screwclamp terminal 2 cable 1...4 mm² - cable stiffness: solid - without cable end
    Power circuit : screwclamp terminal 1 cable 1...35 mm² - cable stiffness: flexible - with cable end
    Power circuit : screwclamp terminal 1 cable 1...35 mm² - cable stiffness: flexible - without cable end
    Power circuit : screwclamp terminal 1 cable 1...35 mm² - cable stiffness: solid - without cable end
    Power circuit : screwclamp terminal 2 cable 1...25 mm² - cable stiffness: flexible - with cable end
    Power circuit : screwclamp terminal 2 cable 1...25 mm² - cable stiffness: flexible - without cable end
    Power circuit : screwclamp terminal 2 cable 1...25 mm² - cable stiffness: solid - without cable end
    Power circuit : screwclamp terminal 2 cable 1...35 mm² - cable stiffness: flexible - with cable end
    Power circuit : screwclamp terminal 2 cable 1...35 mm² - cable stiffness: flexible - without cable end
    Power circuit : screwclamp terminal 2 cable 1...35 mm² - cable stiffness: solid - without cable end
    Complementary
    assembly style
    Ready assembled
    coil technology
    Without built-in bidirectional peak limiting diode suppressor
    protective cover
    With
    auxiliary contacts type
    Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    Type mirror contact (1 NC) conforming to IEC 60947-4-1
    auxiliary contact composition
    1 NO + 1 NC
    interlocking type
    Mechanical
    control circuit voltage limits
    0.3...0.6 Uc at 60 °C drop-out 50/60 Hz
    0.8...1.1 Uc at 60 °C operational 50 Hz
    0.85...1.1 Uc at 60 °C operational 60 Hz
    [Ui] rated insulation voltage
    600 V for control circuit certifications CSA
    600 V for control circuit certifications UL
    600 V for power circuit certifications CSA
    600 V for power circuit certifications UL
    690 V for control circuit conforming to IEC 60947-1
    690 V for power circuit conforming to IEC 60947-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947
    overvoltage category
    III
    mounting support
    Plate
    Rail
    flame retardance
    V1 conforming to UL 94
    tightening torque
    Control circuit : 1.7 N.m - on screwclamp terminal - cable 1...2.5 mm² - with screwdriver flat Ø 6 mm
    Control circuit : 1.7 N.m - on screwclamp terminal - cable 1...2.5 mm² - with screwdriver Philips No 2
    Power circuit : 5 N.m - on screwclamp terminal - cable 1...25 mm² hexagonal
    Control circuit : 1.7 N.m - on screwclamp terminal - cable 1...4 mm² - with screwdriver Philips No 2
    Control circuit : 1.7 N.m - on screwclamp terminal - cable 1...4 mm² - with screwdriver flat Ø 6 mm
    Power circuit : 8 N.m - on screwclamp terminal - cable 1...35 mm² hexagonal
    [Ue] rated operational voltage
    <= 1000 V AC 25...400 Hz for power circuit
    [Ith] conventional free air thermal current
    10 A at <= 60 °C for control circuit
    80 A at <= 60 °C for power circuit
    Irms rated making capacity
    1000 A at 440 V for power circuit conforming to IEC 60947
    140 A AC for control circuit conforming to IEC 60947-5-1
    rated breaking capacity
    1000 A at 440 V for power circuit conforming to IEC 60947
    associated fuse rating
    10 A gG for control circuit conforming to IEC 60947-5-1
    125 A gG at <= 690 V coordination type 2 for power circuit
    160 A gG at <= 690 V coordination type 1 for power circuit
    average impedance
    At 50 Hz - Ith 80 A for power circuit
    power dissipation per pole
    6.3 W AC-3 - Ith 80 A
    inrush power in VA
    200 VA at 20 °C (cos φ: 0.75)
    220 VA at 20 °C (cos φ: 0.75)
    hold-in power consumption in VA
    20 VA at 20 °C (cos f 0.3) 50 Hz
    22 VA at 20 °C (cos f 0.3) 60 Hz
    26 VA at 20 °C (cos f 0.3) 50 Hz
    26 VA at 20 °C (cos f 0.3) 60 Hz
    operating time
    12...26 ms closing
    4...19 ms opening
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    6000000 cycles
    operating rate
    3600 cyc/h at <= 60 °C
    minimum switching current
    5 mA for control circuit
    minimum switching voltage
    17 V for control circuit
    non-overlap time
    1.5 ms on de-energisation between NC and NO contacts
    1.5 ms on energisation between NC and NO contacts
    insulation resistance
    > 10 MOhm for control circuit
    height
    132 mm
    width
    165 mm
    depth
    142 mm
    product weight
    2.4 kg
    Environment
    standards
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    CSA C22.2 No 14
    product certifications
    BV
    CCC
    CSA
    DNV
    GL
    GOST
    LROS (Lloyds register of shipping)
    RINA
    UL
    IP degree of protection
    IP2x conforming to IEC 60529
    IP2x conforming to VDE 0106
    protective treatment
    TH (pollution degree: 3) conforming to IEC 60068
    ambient air temperature for operation
    -5...60 °C
    ambient air temperature for storage
    -60...80 °C
    permissible ambient air temperature around the device
    -40...70 °C at Uc
    operating altitude
    3000 m without derating in temperature
    fire resistance
    850 °C conforming to IEC 60695-2-1
    shock resistance
    10 gn contactor closed
    8 gn contactor opened
    vibration resistance
    2 gn 5...300 Hz contactor opened
    3 gn 5...300 Hz contactor closed
    heat dissipation
    6...10 W at 50 Hz for control circuit
    Contractual warranty
    Warranty period
    18 months