
reversing contactor TeSys LC2-D - 3 poles - AC-3 - 440 V 65 A - coil 48 V AC
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 1000 V AC 25...400 Hz for power circuit[Ie] rated operational current 80 A (<= 40 °C) at <= 440 V AC AC-1 for power circuit65 A (<= 60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 30 kW at 380...400 V AC 50/60 Hz37 kW at 415 V AC 50/60 Hz37 kW at 440 V AC 50/60 Hz37 kW at 500 V AC 50/60 Hz37 kW at 660...690 V AC 50/60 Hz18.5 kW at 220...230 V AC 50/60 Hzmotor power HP (UL / CSA) 50 hp at 575...600 V AC 50/60 Hz for 3 phases motors20 hp at 220...240 V AC 50/60 Hz for 3 phases motors50 hp at 460...480 V AC 50/60 Hz for 3 phases motors10 hp at 230...240 V AC 50/60 Hz for 1 phase motors5 hp at 115 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC 50 Hz[Uc] control circuit voltage 48 V AC 50 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuitIrms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947-4140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 1000 A at 500 V conforming to IEC 609471000 A at 220/415/440 V for power circuit conforming to IEC 60947630 A at 690 V conforming to IEC 60947[Icw] rated short-time withstand current 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit520 A <= 40 °C 10 s power circuit900 A <= 40 °C 1 s power circuit110 A <= 40 °C 10 min power circuit260 A <= 40 °C 1 min power circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1average impedance 1 mOhm at 50 Hz - Ith 80 A for power circuit[Ui] rated insulation voltage 1000 V for power circuit conforming to IEC 60947-4-1600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 1.4 Mcycles 80 A AC-1 <= 440 V1.5 Mcycles 65 A AC-3 <= 440 Vpower dissipation per pole 4.2 W AC-36.4 W AC-1safety cover Withinterlocking type Mechanicalmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications ULCSACCCEACGLBVDNVRINAconnections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminals 1 cable(s) 2.5...25 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminals 2 cable(s) 2.5...16 mm² - cable stiffness: flexible - without cable endPower circuit : screw clamp terminals 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - with cable endPower circuit : screw clamp terminals 1 cable(s) 2.5...25 mm² - cable stiffness: flexible - without cable endPower circuit : screw clamp terminals 2 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminals 1 cable(s) 2.5...25 mm² - cable stiffness: flexible - with cable endtightening torque Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit : 5 N.m - on screw clamp terminalsPower circuit : 5 N.m - on screw clamp terminals - with screwdriver flat Ø 8 mmoperating time 20...26 ms closing8...12 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 16000000 cyclesoperating rate 3600 cyc/h at <= 55 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits 0.85...1.1 Uc operational at 55 °C, AC 60 Hz0.3...0.6 Uc drop-out at 55 °C, AC 60 Hz0.3...0.6 Uc drop-out at 55 °C, AC 50/60 Hz0.8...1.1 Uc operational at 55 °C, AC 50/60 Hzinrush power in VA 200 VA at 20 °C (cos ϕ 0.75) 50 Hz220 VA at 20 °C (cos ϕ 0.75) 60 Hzheat dissipation 6...10 W at 50/60 Hzauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...55 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 960 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzShocks contactor open 8 Gn for 11 msVibrations contactor closed 3 Gn, 5...300 HzShocks contactor closed 10 Gn for 11 msheight 127 mmwidth 165 mmdepth 142 mmproduct weight 2.4 kg -
Documents and Downloads
Language- English
CertificateSizeAdd to My DocumentsCCC TeSys D - LC.D40-65, Czech Republic (Version 1.0)Declaration of conformitySizeAdd to My DocumentsEU Declaration TeSys D - LC.D40-65 (Version 1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.