    Schneider Eletric LC1K09008P7 Picture

    Range: TeSys K

    Contactors

    LC1K09008P7

    Schneider Eletric LC1K09008P7 Picture
    Range: TeSys K

    Contactors

    LC1K09008P7

    TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 <= 440 V 20 A - 230 V AC coil

    Show more characteristics >
    • Price
      24.19 GBP
    Add to My Favourites Remove from My Favourites

    • Main
      range
      TeSys
      product or component type
      Contactor
      product name
      TeSys K
      device short name
      LC1K
      device application
      Control
      contactor application
      Resistive load
      Complementary
      utilisation category
      AC-1
      poles description
      4P
      pole contact composition
      2 NO + 2 NC
      [Ue] rated operational voltage
      690 V AC 50/60 Hz for power circuit
      control circuit type
      AC 50/60 Hz
      [Uc] control circuit voltage
      230 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      8 kV
      overvoltage category
      III
      [Ith] conventional free air thermal current
      20 A at <= 50 °C for power circuit
      Irms rated making capacity
      110 A AC for power circuit conforming to NF C 63-110
      110 A AC for power circuit conforming to IEC 60947
      rated breaking capacity
      110 A at 415 V conforming to IEC 60947
      110 A at 440 V conforming to IEC 60947
      80 A at 500 V conforming to IEC 60947
      110 A at 220...230 V conforming to IEC 60947
      110 A at 380...400 V conforming to IEC 60947
      70 A at 660...690 V conforming to IEC 60947
      associated fuse rating
      25 A gG at <= 440 V for power circuit
      25 A aM for power circuit
      average impedance
      3 mOhm at 50 Hz - Ith 20 A for power circuit
      [Ui] rated insulation voltage
      600 V for power circuit conforming to CSA C22.2 No 14
      690 V for power circuit conforming to IEC 60947-4-1
      600 V for power circuit conforming to UL 508
      inrush power in VA
      30 VA at 20 °C
      hold-in power consumption in VA
      4.5 VA at 20 °C
      heat dissipation
      1.3 W
      control circuit voltage limits
      0.2...0.75 Uc at <= 50 °C drop-out
      0.8...1.15 Uc at <= 50 °C operational
      connections - terminals
      Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
      Screw clamp terminals 1 cable(s) 0.34...2.5 mm² - cable stiffness: flexible - with cable end
      Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
      Screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end
      operating rate
      3600 cyc/h
      signalling circuit frequency
      <= 400 Hz
      mounting support
      Rail
      Plate
      tightening torque
      1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
      1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      operating time
      10...20 ms coil de-energisation and NO opening
      5...15 ms coil energisation and NC opening
      10...20 ms coil energisation and NO closing
      15...25 ms coil de-energisation and NC closing
      safety reliability level
      B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
      mechanical durability
      10 Mcycles
      electrical durability
      0.18 Mcycles 20 A AC-1 at Ue <= 440 V
      mechanical robustness
      Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
      Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
      Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
      height
      58 mm
      width
      45 mm
      depth
      57 mm
      product weight
      0.18 kg
      Environment
      standards
      BS 5424
      IEC 60947
      NF C 63-110
      VDE 0660
      product certifications
      UL
      CSA
      IP degree of protection
      IP2x conforming to VDE 0106
      protective treatment
      TC conforming to IEC 60068
      TC conforming to DIN 50016
      ambient air temperature for operation
      -25...50 °C
      ambient air temperature for storage
      -50...80 °C
      operating altitude
      2000 m without derating in temperature
      flame retardance
      V1 conforming to UL 94
      Requirement 2 conforming to NF F 16-101
      Requirement 2 conforming to NF F 16-102
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  0633  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Available End of life manual
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 23/01/18
      Size 623.9 KB
      CAD
      Date
      Size
      Add to My Documents
      CONTACTOR
      Date 19/12/17
      Size 494.2 KB
      Date 19/12/17
      Size 706.6 KB
      CONTACTOR
      Date 19/12/17
      Size 519.8 KB
      Date 19/12/17
      Size 257.4 KB
      Date 19/12/17
      Size 759.2 KB
      Certificate
      Date
      Size
      Add to My Documents
      Date 14/07/18
      Size 3.7 MB
      Date 10/11/17
      Size 2.6 MB
      Date 14/07/18
      Size 747.3 KB
      Declaration of conformity
      Date
      Size
      Add to My Documents
      Date 05/12/17
      Size 717.7 KB
      End of life manual
      Date
      Size
      Add to My Documents
      Date 21/09/17
      Size 213 KB
      Product environmental
      Date
      Size
      Add to My Documents
      Date 21/09/17
      Size 189.1 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.