-
Characteristics
Main range of product TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadutilisation category AC-1control circuit type ACcoil type Standardpoles description 4Ppole contact composition 4 NO[Ie] rated operational current 80 A (<= 60 °C) AC AC-1 for power circuitmotor power hp 10 hp at 230/240 V AC 60 Hz for 1P motors conforming to CSA10 hp at 230/240 V AC 60 Hz for 1P motors conforming to UL20 hp at 200/208 V AC 60 Hz for 3P motors conforming to CSA20 hp at 200/208 V AC 60 Hz for 3P motors conforming to UL20 hp at 230/240 V AC 60 Hz for 3P motors conforming to CSA20 hp at 230/240 V AC 60 Hz for 3P motors conforming to UL5 hp at 115 V AC 60 Hz for 1P motors conforming to CSA5 hp at 115 V AC 60 Hz for 1P motors conforming to UL50 hp at 460/480 V AC 60 Hz for 3P motors conforming to CSA50 hp at 460/480 V AC 60 Hz for 3P motors conforming to UL50 hp at 575/600 V AC 60 Hz for 3P motors conforming to CSA50 hp at 575/600 V AC 60 Hz for 3P motors conforming to UL[Uc] control circuit voltage 220 V AC 50/60 Hzconnections - terminals Control circuit : screw clamp terminal 1 cable 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminal 2 cable 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminal 2 cable 1...4 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminal 1 cable 1...35 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminal 2 cable 1...25 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminal 2 cable 1...35 mm² - cable stiffness: solid - without cable endComplementary coil technology Without built-in bidirectional peak limiting diode suppressorprotective cover Withauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1control circuit voltage limits 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz0.8...1.1 Uc at 60 °C operational 50 Hz0.85...1.1 Uc at 60 °C operational 60 Hz[Ui] rated insulation voltage 600 V for control circuit certifications CSA600 V for control circuit certifications UL600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for control circuit conforming to IEC 60947-1690 V for power circuit conforming to IEC 60947-1[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947overvoltage category IIImounting support PlateRailflame retardance V1 conforming to UL 94tightening torque Power circuit : 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mmControl circuit : 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2Control circuit : 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mmPower circuit : 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm[Ue] rated operational voltage <= 690 V AC 25...400 Hz for power circuit[Ith] conventional free air thermal current 10 A at <= 60 °C for control circuit80 A at <= 60 °C for power circuitIrms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947140 A AC for control circuit conforming to IEC 60947-5-1rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 2 for power circuit160 A gG at <= 690 V coordination type 1 for power circuitaverage impedance At 50 Hz - Ith 80 A for power circuitpower dissipation per pole 6.4 W AC-1inrush power in VA 140 VA at 20 °C (cos f 0.75)160 VA at 20 °C (cos f 0.75)hold-in power consumption in VA 13 VA at 20 °C (cos f 0.3) 60 Hz15 VA at 20 °C (cos f 0.3) 50 Hzoperating time 12...26 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6000000 cyclesoperating rate 3600 cyc/h at <= 60 °Cminimum switching current 5 mA for control circuitminimum switching voltage 17 V for control circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contacts1.5 ms on energisation between NC and NO contactsinsulation resistance > 10 MOhm for control circuitheight 127 mmwidth 85 mmdepth 130 mmproduct weight 1.44 kgEnvironment standards EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508CSA C22.2 No 14product certifications BVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)RINAULIP degree of protection IP2x conforming to IEC 60529IP2x conforming to VDE 0106protective treatment TH (pollution degree: 3) conforming to IEC 60068ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1shock resistance 10 gn contactor opened15 gn contactor closedvibration resistance 2 gn 5...300 Hz contactor opened4 gn 5...300 Hz contactor closedheat dissipation 4...5 W at 50/60 Hz for control circuitOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Chinese
CADSizeAdd to My DocumentsTeSys D - Contactor - LC1D4000/LC1D6500 - 4P-AC coil (Version 1.0)CertificateSizeAdd to My DocumentsCCC TeSys D - LC.D40-65, Czech Republic (Version 1.0)Declaration of conformitySizeAdd to My DocumentsEU Declaration TeSys D - LC.D40-65 (Version 1.0)End of Life InformationSizeAdd to My DocumentsTeSys D 40, 50, 65A - EoLi (Version 1.0)EU RoHS DeclarationSizeAdd to My DocumentsProduct Environmental ProfileSizeAdd to My DocumentsREACh DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.