soft starter for asynchronous motor - ATS01 - 85 A - 230..690V - 22..75 KW

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Altistart 01
    product or component type
    Soft starter
    product destination
    Asynchronous motors
    product specific application
    Simple machine
    device short name
    ATS01
    network number of phases
    3 phases
    [Us] rated supply voltage
    230...690 V - 15...10 %
    motor power kW
    22 kW, 3 phases at 230 V
    45 kW, 3 phases at 400 V
    75 kW, 3 phases at 690 V
    motor power hp
    30 hp, 3 phases at 230 V
    50 hp, 3 phases at 400 V
    60 hp, 3 phases at 460 V
    75 hp, 3 phases at 575 V
    IcL starter rating
    85 A
    utilisation category
    AC-53B conforming to EN/IEC 60947-4-2
    current consumption
    255 A at nominal load
    type of start
    Start with voltage ramp
    power dissipation in W
    23 W at full load and at end of starting
    514 W in transient state
    Complementary
    assembly style
    With heat sink
    function available
    Integrated bypass
    supply voltage limits
    195…759 V
    supply frequency
    50...60 Hz - 5...5 %
    network frequency
    47.5...63 Hz
    output voltage
    <= power supply voltage
    [Uc] control circuit voltage
    110 V AC +/- 10 %
    starting time
    1 s / 360
    12 s / 30
    Adjustable from 1 to 25 s
    deceleration time symb
    Adjustable from 1 to 25 s
    starting torque
    30...80 % of starting torque of motor connected directly on the line supply
    discrete input type
    Internal (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA
    discrete input voltage
    24 V
    discrete input logic
    Positive logic LI1, LI2, BOOST at State 0: <= 3 V at State 1: >= 10 V
    discrete output current
    2 A DC-13
    3 A AC-15
    discrete output type
    Relay outputs R1A, R1C
    discrete output voltage
    24 V DCrelay outputs
    250 V ACrelay outputs
    minimum switching current
    10 mA at 17 V DCfor relay outputs
    display type
    1 LED (green)for starter powered up
    1 LED (yellow)for nominal voltage reached
    tightening torque
    0.7 N.m
    5 N.m
    electrical connection
    Earth connection: tinned connector fixed using Ø 6 mm screws
    4 mm screw clamp terminal - rigid 1 6...35 mm² power circuit
    Screw connector - rigid 1 0.75...1.5 mm² control circuit
    4 mm screw clamp terminal - rigid 2 6...25 mm² power circuit
    Screw connector - rigid 2 0.75...1.5 mm² control circuit
    4 mm screw clamp terminal - flexible with cable end 1 4...25 mm² power circuit
    Screw connector - flexible with cable end 1 0.75...1.5 mm² control circuit
    4 mm screw clamp terminal - flexible without cable end 1 6...25 mm² power circuit
    Screw connector - flexible without cable end 1 0.75...1.5 mm² control circuit
    4 mm screw clamp terminal - flexible with cable end 2 4...16 mm² power circuit
    Screw connector - flexible with cable end 2 0.75...1.5 mm² control circuit
    4 mm screw clamp terminal - flexible without cable end 2 6...25 mm² power circuit
    Screw connector - flexible without cable end 2 0.75...1.5 mm² control circuit
    marking
    CE
    operating position
    Vertical +/- 10 degree
    height
    146 mm
    width
    180 mm
    depth
    126 mm
    net weight
    3.8 kg
    compatibility code
    ATS01N2
    Environment
    electromagnetic compatibility
    Conducted and radiated emissions level B conforming to IEC 60947-4-2
    Damped oscillating waves level 3 conforming to IEC 61000-4-12
    Electrostatic discharge level 3 conforming to IEC 61000-4-2
    EMC immunity conforming to EN 50082-1
    EMC immunity conforming to EN 50082-2
    Harmonics conforming to IEC 1000-3-2
    Harmonics conforming to IEC 1000-3-4
    Immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6
    Immunity to electrical transients level 4 conforming to IEC 61000-4-4
    Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
    Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11
    Voltage/current impulse level 3 conforming to IEC 61000-4-5
    standards
    EN/IEC 60947-4-2
    product certifications
    CCC
    UL
    B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
    C-Tick
    GOST
    CSA
    IP degree of protection
    On front panel: IP20
    pollution degree
    3 conforming to IEC 60664-1
    3 conforming to UL 508
    vibration resistance
    2 gn
    shock resistance
    8 gnfor 11 ms conforming to EN/IEC 60068-2-27
    relative humidity
    5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
    ambient air temperature for operation
    0…55 °C
    ambient air temperature for storage
    -25…70 °C conforming to EN/IEC 60947-4-2
    operating altitude
    <= 2000 m without derating
    > 2000 m with current derating of 0.5 % per additional 100 m
    Contractual warranty
    Warranty
    18 months
  • Documents and Downloads

    Instruction sheet
    Date
    Size
    Add to My Documents
    Instruction sheet - ATS01N2..Q/LY (Version 03)
    Date 14/02/18
    Size 796.8 KB
    CAD
    Date
    Size
    Add to My Documents
    Soft start/soft stop unit Power : 18.5 to 45 kW - U 3-phase = 230 to 600 V or 400 V (Version 1.0)
    Soft start/soft stop unit Power : 18.5 to 45 kW - U 3-phase = 230 to 600 V or 400 V (Version 1.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.