| FA166899 | What is the maximum earth fault loop impedance Zs for the gv7? What values are taken into consideration to calculate the Zs values? For a TN system, section 413-02-08 of BS7671 defines the maximum earth fault loop impedance based on the following condition being met:
... |
| FA166810 | How do I find the default IP address of an Advantys STB network interface module? The default IP address can be determined using a tool within the Advantys configuration software;
Follow the steps below;
Select 'connection settings'... |
| FA27930 | How can I create and modify a password in a ZELIO LOGIC SR2 and SR3? Entering the password
Go to: CONFIGURATION menu, PASSWORD section
Initially, the key is not displayed and each digit is set to 0. The message ENTER... |
| FA22735 | I don't like the tone of the audible module (buzzer) of the XVPC signal towers. Do you have other versions? The audible signaling units (buzzers) on XVPC signal towers are supplied with the option to choose one of 10 tones.
Method for changing the factory-set... |
| FA22711 | What mounting tips can you give for single beam polarised reflex type detectors with the mute function connected to an XPSCM11 Summary of the mute function of an XPSCM Preventa module:
The Preventa XPSCM module mute mechanism allows materials to be transported across the... |
| FA22710 | What mounting tips can you give for single beam proximity detectors with the muting function connected to an XPSCM1144? Summary of the muting function of an XPSCM Preventa module:
The XPSCM Preventa module muting mechanism allows materials to be transported across... |
| FA23721 | What is the operating principle of a detector for XSAV type rotation control? Advantage and preferred uses
XSAVxx inductive sensors for rotation control have the special feature of combining data acquisition functions and... |
| FA24954 | How can the pressure be adjusted on an electromechanical pressure switch (XMLA, XMLB, XMLC) without an display? The pressure is adjusted by means of the adjusting screw located on top of the product.
When the product does not have a display, we recommend using... |
| FA22849 | Can I purchase separately the contact block or the rotary head of a ZCKJxx limit switch? We cannot supply either the contact block or the rotary head of the ZCKJxx body separately, because the actuation angle of the head is set by adjusting... |
| FA164631 | What is the default IP address of a TSXETG30** FactoryCast HMI Gateway Module? The default IP address for a TSXETG30** module is 10.10.xx.xx, the last two octets being derived from the last two octets of the MAC address. The... |