FA141863What replaced XPSCE? What are the differences between XPSCE and the new XPSCM?
XPS-CE Replaced by XPS-CM   XPSCE (old model)                                                       XPSCM (new model) XPS-CM has 3 extra solid...
FA141670What replaced XPSASF? What are the differences between XPSASF and the new XPSAK?
XPS-ASF Replaced by XPS-AK   XPSAFS (old model)                                                    XPSAK (new model) XPS-AK has one extra N/O...
FA142425Is there an enclosure for GV3, to make an enclosed starter? Can we fit GV3P, GV3L and GV3ME? Can we mount LC1 contactor?
Yes, there is an enclosure that can take the new GV3P and GV3L, plus there’s space to mount a contactor inside. The new enclosures GV3PC aren’t suitable...
FA142669Did the appearance of Tesys D contactors and control relays change? What changed on the “looks” for LC1D contactors (sizes LC1D09 to LC1D38) and CAD control relays?
Yes, there is an evolution happening during the 2nd quarter of 2012, in which will change slightly their appearance. This change will affect the Tesys...
FA142680What equipment uses the TSXCUSB485 USB converter?
Here are some of our products that use this USB converter:   XPSMC             safety modules TSX Micro        PLC’s Premium           PLC’s Atrium             PLC’s M238               PLC’s Twido              PLC’s XBT...
FA142687What is the difference between an LUB12 32 & LUB120 320 Tesys U starter?
The Tesys U non reversing starter controller offers two types of power base units in its range LUB12 & LUB120 (0 – 12A, 5.5kw at 400V) LUB32 & LUB320...
FA141939What replaced Integral 18 and 32 DOL starters - LD1, LD3, LD4, LB1 and LB6?
Integral Replaced by Tesys U   Integral 18 and Integral 32 DOL (old model)                                          Tesys U - LUB (new model)                                ...
FA141913What can I use to replace DOL Integral 18 and 32, LD1, LD3 and LD4? Can I replace Integral 18 and 32 using contactors and MCB’s?
Yes, you can, using the kit we have prepared:   Integral 18 and Integral 32 replaced by LC1D+GV2 New kit, using contactors Tesys D LC1D + MCB’s...
FA141941What replaced Integral 18 and 32 DOL reversing starters – LD5, LB1 and LB6?
What replaced Integral 18 and 32 DOL reversing starters – LD5, LB1 and LB6?   Integral Replaced by Tesys U   Integral 18 and 32 reversing DOL (old...
FA141914What can I use to replace Integral 18 and 32, LD5 reversing DOL? Can I replace Integral 18 and 32 using contactors and MCB’s?
Yes, you can, using the kit we have prepared:   Integral 18 and Integral 32 reversing DOL replaced by LC2D+GV2 New kit, using contactors Tesys...