| FA23075 | Can I install a potentiometer, part number SZ1RV1202, in an XACA enclosure? No. There are two reasons preventing a potentiometer, part number SZ1RV1202, from being installed in an XACA enclosure:
1. An SZ1RV1202 potentiometer... |
| FA22954 | What power supplies should I use to supply light curtains? Schneider Electric guarantees the correct operation of its light curtains if they are powered with the following modules:
ABL8RPS24030: Universal... |
| FA22734 | What is the maximum number of units that can be assembled on an XVP beacon tower? It is possible to stack a combination of up to 5 illuminated and audible units (one audible unit maximum) to create an XVP beacon tower.
Example... |
| FA22737 | Can I mix lighting units using incandescent lamps and lighting units using LED lamps on the XVP range of illuminated beacons On the XVP range of illuminated beacons and tower lights, it is technically possible to mix lighting units using incandescent lamps and lighting units... |
| FA141655 | Will Zelio Soft 2 V4.5 work on Windows 7 64 bit?
Yes, the only current issue that arises is when it comes to communicate between the PC/Laptop and the Zelio Logic Relay, if you use the USB cable... |
| FA144717 | What are the differences between 220VAC, 230VAC and 240VAC Mains Supplies and what voltage equipment should I use? For many years, mainland Western Europe has used a mains electricity supply rated at nominally 220VAC 50Hz. The UK used 240VAC 50Hz.
Currently,... |
| FA141633 | What replaced XPSAPF? What are the differences between XPSAPF and the new XPSAR? XPS-APF replaced by XPS-AR
XPSAPF (old model) XPSAR (new model)
XPS-AR has 2 extra solid... |
| FA141599 | How to overcome compatibility issues with EEPROM memory cartridges SR2MEM02 and SR2MEM01? SR2MEM01
For firmware (software embedded in the Smart Relay) versions ≤ 2.4
It will not work with software versions higher than 2.4
SR2MEM02
For... |
| FA141555 | How to check the firmware and hardware version on the Zelio Logic Smart relay?
Check the firmware on the front of the screen (LCD display) of Zelio Smart Relay.
Check the firmware on the software,... |
| FA141635 | Can I connect an SR2 or SR3 Zelio Logic Smart Relay to an HMI, separate display screen?
Yes, you can connect the SR2 or SR3 to a small HMI, this HMI comes included in a kit, starter-kit HMISTO & Zelio Logic – reference: VJDSTKSTOSR2
The... |