| FA22735 | I don't like the tone of the audible module (buzzer) of the XVPC signal towers. Do you have other versions? The audible signaling units (buzzers) on XVPC signal towers are supplied with the option to choose one of 10 tones.
Method for changing the factory-set... |
| FA22736 | What is the degree of protection of the XVP range? The degree of protection of the audible and illuminated units in the XVP range of illuminated beacons and indicator banks is as follows:
Illuminated... |
| FA22737 | Can I mix lighting units using incandescent lamps and lighting units using LED lamps on the XVP range of illuminated beacons On the XVP range of illuminated beacons and tower lights, it is technically possible to mix lighting units using incandescent lamps and lighting units... |
| FA22714 | Dynamic periodic monitoring of dual body valves on an XPSPVK eccentric press Presses used for cold working of metals must be systematically and regularly checked.
This check also affects the safety function provided by the... |
| FA22723 | What material is used in and what is the surface treatment for ZB2Bxx sub-bases? ZB2Bxx sub-bases are made of chromium plated ZnAl4. |
| FA22719 | Can the XPE on/off foot switches be used to perform an emergency stop function? No, as due to their mechanical design, there is nothing to prevent an object from getting under the foot switch and preventing actuation of the contact.... |
| FA22721 | Why are XPE foot switches only available with quick-break contacts whereas older models were available with slow-break contacts? For many years it was not possible to comply with the rules on positive opening using quick-break contacts. For this reason products were designed... |
| FA22712 | Simulation of a fault on one of the 2 valve flaps (dynamic monitoring) managed by an XPSPVK The presses used for the cold working of metals must be routinely and regularly checked.
This check also affects the safety function provided by... |
| FA22711 | What mounting tips can you give for single beam polarised reflex type detectors with the mute function connected to an XPSCM11 Summary of the mute function of an XPSCM Preventa module:
The Preventa XPSCM module mute mechanism allows materials to be transported across the... |
| FA22710 | What mounting tips can you give for single beam proximity detectors with the muting function connected to an XPSCM1144? Summary of the muting function of an XPSCM Preventa module:
The XPSCM Preventa module muting mechanism allows materials to be transported across... |